Evaluation of Electric and Magnetic Fields Distribution and SAR with the Help of Intensity of Time Averaged Electromagnetic Wave
P. Ashok Kumar1, Ch. R. Phani Kumar2 

1P. Ashok Kumar, Assistant Professor, Avanthi Institute of Engineering & Technology, Visakhapatnam, Andhra Pradesh
2Dr Ch. R. Phani Kumar, Assistant Professor, GITAM Deemed to be University, Visakhapatnam, Andhra Pradesh

Manuscript received on 17 March 2019 | Revised Manuscript received on 21 March 2019 | Manuscript published on 30 July 2019 | PP: 5495-5498 | Volume-8 Issue-2, July 2019 | Retrieval Number: B2631078219/19©BEIESP | DOI: 10.35940/ijrte.B2631.078219
Open Access | Ethics and Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: Potential Risk from Exposure to EMF have been explored for a long time. Different research endeavours have tended to security rules to Protect the Human body from EM penetration. The study of Electromagnetic fields and non-ionizing effects on human body is a very useful due to possible health effects that these many electromagnetic field can cause in humans. At the point when an Electric or Magnetic field Penetrates into body, it is weakened and some portion of is assimilated inside the body tissue. Impact of EM on Human body relies upon force of Electromagnetic field and distance of EM source to human body. Specific Absorption Rate (SAR) is a parameter used to estimate amount of energy absorbed by a human body. SAR Is depends on Frequency and Intensity of Electromagnetic wave. Broad Research is already done on Reduction of SAR in the case over usage of Mobile phones units but SAR minimization in Medical Application like MRI is always a challenge to Researchers. The advantages of Magnetic Resonance imaging (MRI) have made it the Radiological Method of Choice for an extraordinary Number of analytic Procedures, but the drawback is options are limited in the case of patients who are having implantable devices, The SAR Value is increased due to implantable devices because of temperature Rise. Leakage Magnetic field from the diagnosis instruments leads to hazardous to medical Personnel. this Paper is a initiated work on Study of SAR considering the intensity of electromagnetic wave and assessment of SAR in case of leakage of Magnetic field leakage.
Index Terms: EMF, MRI, Leakage Magnetic Field, Specific Absorption Rate (SAR)
Scope of the Article: Performance Evaluation of Networks